MOXA Media Konverter: Fiber Optic (Glasfaser) nach RS232/RS422/485
|
|
|
|
|
RS232 nach RS422/485 Konverter
|
|
TCF-142M
|
|
Preis € Restbestand!
|
|
|

|
|
The TCF-142 Series serial to fiber converter is equipped with a multiple interface circuit that can handle conversion between either RS-232 or RS-422/485 serial interfaces, and multi-mode or single-mode optical fiber. TCF-142 converters are used to extend serial transmission distance up to 2 km (TCF-142-M multi-mode fiber) or up to 20 km (TCF-142-S single-mode fiber).
|
|
|
|
Technische Dokumentation als PDF-Datei
|
|
|
|
|
|
|
|
|
|
|
TCF-142-M/-S/-T
|
|
Preis €
|
|
|

|
|
The TCF-142 media converter is equipped with a multiple interface circuit that can handle RS-232 or RS-422/485 serial interfaces and multi-mode or single-mode fiber. TCF-142 converters are used to extend serial transmission up to 5 km (TCF-142-M with multi-mode fiber) or up to 40 km (TCF-142-S with single-mode fiber). The TCF-142 can be configured to convert either RS-232 signals, or RS-422/485 signals, but not both at the same time.
# “Ring” and “Point-to-Point” transmission # Extends RS-232/422/485 transmission up to: * 40 km with single-mode—TCF-142-S * 5 km with multi-mode—TCF-142-M # Compact size # Decreases signal interference # Protects against electrical interference and chemical corrosion # Supports baudrates of 50 bps to 921.6 Kbps # Wide temperature models available (-40 to 75°C)
Automatic Baudrate Detection
The TCF-142 can automatically detect the serial baudrate. This is an extremely convenient feature. Even if a device€s baudrate is changed, the signal will still be transmitted through the media converter without any data loss.
The TCF-142 can be used to connect serial devices to a fiber ring. To form the ring, connect the Tx port of one TCF-142 to the Rx port of a neighboring converter. Once the ring is set up, simply use the DIP switches to configure the TCF-142 converters for “ring mode.” When one node transmits a signal, the signal travels around the ring until it returns back to the transmitting unit, which then blocks the signal. With the TCF-142, you can set up fiber rings that have a total circumference of up to 100 km.
|
|
|
|
Technische Dokumentation als PDF-Datei
|
|
|
|
|
|
|
|
|
|
|
TCF-142-RM
|
|
Preis € neu
|
|
|

|
|
The TCF-142-RM series of serial-to-fiber converters are slide-in modules that work with the TRC-190 chassis. The modules convert from the RS-232, RS-422, or RS-485 signal to a fiber optic signal.
Features:
› Extend RS-232/422/485 transmission up to: • 40 km with single mode • 5 km with multi-mode › 1K or 150K ohm adjustable pull high/low resistor › “Ring" and "Point-to-Point" transmission supported
Das 19” Racksystem TRC-190 für TCF-142-RM siehe unten
|
|
|
|
Technische Dokumentation als PDF-Datei
|
|
|
|
|
|
|
|
|
|
|
TRC-190
|
|
Preis €
|
|
|

|
|
The TRC-190 series provides 19 slots for media converter modules such as the TCF-142-RM series. A TRC-190 chassis comes with one AC or DC power input, with an optional redundant power expansion module available for greater reliability. The TRC-190 series' power input module supports the hot-swap feature. 19-inch chassis for rackmount use
› 19-inch chassis for rackmount use › 19 slots for high density applications › Supports hot-swap and dual power input with redundancy › Fan-less design chassis for reducing repair time
|
|
|
|
Technische Dokumentation als PDF-Datei
|
|
|
|
|
|
|
|
|
TCF-90
|
|
Preis €
|
|
|

|
|
The TCF-90 is a compact media converter that transmits RS-232 signals over optical fiber. Power is derived from either the serial port or an external power source. The TCF-90 extends RS-232 transmission up to 5 km with multi-mode fiber, or up to 40 km with single-mode fiber. A pair of TCF-90 converters can be used to connect two RS-232 devices with optical fiber in full duplex mode. The optical fiber isolates the data signals from dangerous increases in ground potential, ground loops, and electrical EMI/RFI noise, and enhances data security by eliminating the harmful effects of RF radiation and susceptibility to electromagnetic radiation.
# Use either external power or power over serial # Extends RS-232 transmission up to:
* 40 km with single-mode—TCF-90-S * 5 km with multi-mode—TCF-90-M
# Reduces signal interference # Protects against electrical interference or chemical corrosion # 15 KV ESD protection for serial signals # Baudrates up to 921.6 Kbps
|
|
|
|
Technische Dokumentation als PDF-Datei
|
|
|
|
|
|
|
|
|
|
|
TCF-1150
|
|
Preis € neu
|
|
|

|
|
The ICF-1150 series support 2 serial ports, with a D-sub connector for RS-232 communication and a removable terminal block for RS-422 or RS-485 communication. The 3 ports (2 serial ports and one fiber port) are completely independent. When an ICF-1150 converter receives data from any one port, it will send the data out through the other 2 ports. For example, once the ICF-1150 converter receives a command from the remote master through the fiber port, it will convert the signal and send the command through the RS-232 and RS-422/485 ports at the same time. If the user is monitoring a system running on an RS-485 network, there is no need to use an additional RS-232 to RS-485 converter to connect the laptop computer's serial port to the RS-485 bus.
€ş RS-232, fiber, and RS-422/485 3-way communication €ş Rotary switch to change the pull high/low resistor value €ş Extend RS-232/422/485 transmission up to: · 40 km with single-mode · 5 km with multi-mode €ş 3-way Galvanic Isolation (for "I" model only) €ş - 40 to 85°C wide temperature models available €ş Class I, Div. II certification (Pending)
|
|
|
|